NE215
Programming field 4
Line 43
Baud rate
0 * 4800 baud
1 2400 baud
2 1200 baud
3 600 baud
Line 44
Parity
0 * Even parity
1 Odd parity
2 No parity
Line 45
Address
* 0
1-99
Line 46
Stop bits
0 * 1 Stop bit
1 2 Stop bits
At the conclusion of these programming lines, a broken line will
appear in the display, signifying the competion of the fourth
programming segment.
To leave programming mode
Press the key.
Counter now reverts to the operating mode.
Reprogramming the counter
Switch on the instrument and press the key simultaneously.
to the defaults settings
All the programmed values will now revert to their defaults
settings.
5.1 Operating modes
The operating modes are described below.
Step preset
On reaching a preset value, the counter continues to count to the
next preset value. Preset values are always processed in the
sequence: preset value 1, preset value 2. Any values can be chosen.
External or manual resetting can be carried out at any time.
P1- Self-adjusting preset
Preset value P1 serves as a preliminary signal and functions as a
self-adjusting preset. The preliminary signal always switches to the
input value before the final signals is given. Any second preset value
can be chosen.