9. Programming plan
Lines
11-17
status of lines 1-7
0 parameter to be altered
1 clear resp. input lock
2 skip parameter
Line 22 operation mode
0 step preset
1 main preset
2 parallel comparison
3 P1 trailing preset
Line 24 decimal point
0 no decimal point
1 00000.0
2 0000.00
3 000.000
4 00.0000
Line 25 counting mode
0 track A UP/DOWN signal on track B
1 difference (A-B)
2 total (A+B)
3 track A 90° B single evaluation
4 track A 90° B double evaluation
5 track A 90° B four-times evaluation
Line 26 frequency main counter track A
0 10 kHz
1 25 Hz
2 3 Hz
Line 27 frequency main counter track B
0 10 kHz
1 25 Hz
2 3 Hz
Line 28 switching threshold and input logic
0 switching threshold 6V PNP
1 switching threshold 6V NPN
2 switching threshold 3V PNP
3 switching threshold 3V NPN
Line 29 main counter reset (control input 1)
0 automatic reset and externally static
1 automatic reset and externally differential
2 externally static
3 externally differential
4 externally with "start-function"
Line 31 function control input 2
0 stop
1 hold
2 keylock
3 hour counter on/off
4 offset
5 print (only with interface)
Line 33 output logic digital outputs
0 both outputs normally closed
1 P1 normally open, P2 normally closed
2 P1 normally closed, P2 normally open
3 both outputs normally open
Line 35 momentary signal time P1
0.25 default
0.01 Min.
99.99 Max.
Line 36 momentary signal time P2
0.25 default
0.01 Min.
99.99 Max.