de_BA_FNDx14_FHDx14_IO.doc 12/14 Baumer Electric AG
10.04.2013/hem Frauenfeld, Switzerland
6 Zusammenstellung Parameter
6.1
Tabelle Allgemeine Informationsparameter
SPDU name
SPDU index
Number of Bytes
Format
Range of values
R/W
Comments
General information on sensors
Vendor Name 0X10 18 String ASCII R “Baumer Electric AG“ for all sensors
Product Name 0X12 22 String ASCII R Corresponds with Baumer article
description
Product ID 0X13 8 String ASCII R Corresponds with Baumer article number
Serial Number 0X15 4 String ASCII R Baumer P-Code
Firmware Revision 0X17 8 String ASCII R Baumer Firmware Revision
Application Specific
Name
0X18 8 - - R/W 8 Byte at customer disposal
6.2 Tabelle Betriebsparameter
SPDU name
SPDU index
Number of Bytes
Format
Range of values
R/W
Comments
Teach-in and switching points
Switching points
work
0X40 4 Switching point A (HB, LB)
Switching point B (HB, LB)
50…400 R/W Distance information on switching points,
calculated from the information on Teach-
in position interim
Teach-in positions
interim
0X41 4 Teach-in Position A (HB, LB)
Teach-in Position B (HB, LB)
50…400,
65535
R Distance information on Teach-in position
Sensor functions
Teach function 0X60 1 0 = One point Teach-in
(Reference position)
2 = Two point Teach-in
(ON/OFF-position)
0,2 R/W Selection of Teach mode
Nominal value
quality parameter
0X65 1 1..8 R/W Provided the internal quality parameter
drops below this threshold the switching
output is set.
Quality parameter 0X66 1 1..8 or 255 R
Output functions
Output delay
function
0x71
1 Byte 0 (Subindex 1)
0 = no delay
1 = on delay
2 = off delay
3 = minimum pulse
4 = single shot positive edge
5 = single shot negative edge
0…5 R/W Choose delay funciton
Output delay time 0x72 2 Byte 1…2, time in 1ms 0…1000 R/W Delay time