MB181a - 11114025
Baumer_POGS90-B3_II_DE-EN (13A1)
24
Technical data 11
11 Technical data
11.1 Technical data - electrical ratings
• Voltage supply: 5 VDC ±10 % (version DN ...)
9...30 VDC (version DN ... R)
• Consumption w/o load: ≤90 mA
• Sinewave cycles per turn: 720...5000 (like precised on order)
• Phase shift: 90°
• Reference signal: Zero pulse, width 90°
• Sensing method: Optical
• Output signals: K1, K2, K0 + inverted
• Output circuit: SinCos 1 Vpp
• Difference of SinCos amplitude: ≤20 mV
• Harmonics typ.: -50 dB
• DC offset: ≤20 mV
• Bandwidth: 250 kHz (-3 dB)
• Interference immunity: EN 61000-6-2:2005
• Emitted interference: EN 61000-6-3:2007/A1:2011
• Approvals: UL approval / E256710
11.2 Technical data - mechanical design
• Dimensions (ange): ø115 mm
• Shaft type: ø11 mm solid shaft
• Shaft loading: ≤250 N axial
≤350 N radial
• Flange: EURO ange B10
• Protection DIN EN 60529: IP 66
• Operating speed: ≤10000 rpm (mechanical)
• Operating torque typ.: 2 Ncm
• Rotor moment of inertia: 320 gcm²
• Materials: Housing: aluminium die-cast alloy and stainless steel
Shaft: stainless steel
• Operating temperature: -20...+85 °C
(restricted in potentially explosive environments, see section 2)
• Resistance: IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 11 ms
• Explosion protection: II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
• Connection: Terminal box
• Weight approx.: 1.7 kg
Comentários a estes Manuais