Technical data
Technical data - electrical ratings
Voltage supply 85...265 VAC (50/60 Hz), 10...30 VAC/VDC
Power consumption 1.5 VA, 2 W
Display LCD, 7-segment, 2-lines, backlit
Number of digits 6-digits
Digit height 7 mm (count), 4 mm (preset)
Function Preset counter
Scaling factor 0.0001...9999.99
Count mode Adding or subtracting
Counting frequency 25 Hz (DC trigger: 1 kHz)
Data memory >10 years in EEPROM
Reset Button, electric or automatic
Keylock Yes, electric (keylock)
Outputs relay Potential-free changeover contact
Output holding time 0.01...99.99 s
Standard DIN EN 61010-1 Protection class II, Overvoltage category II
Pollution degree 2
Emitted interference DIN EN 61000-6-3
Interference immunity DIN EN 61000-6-2
Programmable parameters Measuring units, sensor logic,
decimal point, scaling factor, count mode
Approvals UL approvals / E63076, CE conform
Technical data - mechanical design
Ambient temperature 0...+50 ºC
Storing temperature -20...+70 ºC
Relative humidity 80 % non-condensing
E-connection Plug-in screw terminals
Core cross-section 1.5 mm
2
Protection DIN EN 60529 IP 65 face with seal
Operation / keypad Membrane with softkeys
Housing type Built-in housing
Dimensions W x H x L 48 x 48 x 108 mm
Installation depth 108 mm
Mounting Clip frame
Cutout dimensions 45 x 45 mm (+0.6)
Materials Housing: Makrolon 6485 (PC)
Keypad: Polyester
Weight approx. 140 g