9 Programming plan
Line 11-18 Status for Lines 1-8
0
Parameter can be altered
1 Deletion or input inhibited
2 Parameters bypassed
Line 21 Operating mode, main counting system
0 Stage preselection
1 Main preselection
2 Parallel comparison
3 P1 slave preselection
Line 22 Scaling factor, main counting system
1.0000
Minimum value
0.0001 Default value
9999.99 Maximum value
Line 23 Scaling factor, ancillary counting system
1
Minimum value
1 Default value
99 Maximum value
Line 24 Frequency track A
0
10 kHz
1 25 Hz
2 15 Hz
Line 25 Frequency track B
0
10 kHz
1 25 Hz
2 15 Hz
Line 26 Frequency batch counting input
0
10 kHz
1 25 Hz
2 15 Hz
Line 27 Operating modes, inputs
0
Track A and Up/Down
1 Differential counting A - B
2 Summation
3
A 90° B
4
A 90° B x 2
5
A 90° B x 4
Line 28 Decimal point, main counting system
0
No decimal point
1 0000000.0
2 000000.00
3 00000.000
Line 29 Resetting, main counting system
0
Automatic reset and external static
1 Automatic reset and external differentiated
2 External static
3 External differentiated
Line 30 Resetting, ancillary counter
0
Automatic reset and external static
1 Automatic reset and external differentiated
2 External static
3 External differentiated
Line 31 Output P1
0.25 Continuous
0.01 Default
99.99 Maximum
Line 32 Output P2
0.25 Continuous
0.01 Default
99.99 Maximum
Line 33 Output P3
0.25 Continuous
0.01 Default
99.99 Maximum
Line 34 Acceptance of preselections P1, P2, B
0
On
1 Following
Line 35 Address for function key
0 Without function
1 XP
2 P1
3 P2
4 SC
7
Σ
5 XB
6 B1
8
§
Line 36 Function of the batch counter
0
External
1 Internal
2 Tachometer
Line 37 Pulses per unit with tachometer
1.00
Minimum value
0.01 Default value
9999.99 Maximum value
Line 38 Time basis for tachometer function
0
1 second
1 2 seconds
2 3 seconds
3 6 seconds
4 10 seconds
5 20 seconds
6 30 seconds
7 60 seconds
Line 39 Assignment output 3
0
Batch preselection output
1 Zero contact output XP
Line 40 Function input 15
0 XP Stop
1 Operating hours ON/OFF
2 Key and display hold
Line 41 Code
0000
Code not active
:
9999
Line 43 Baud rate
0 4800 Baud
1 2400 Baud
2 1200 Baud
3 600 Baud
Line 44 Parity
0 Even Parity
1 Odd Parity
2 No Parity
Line 45 Address
00 Default
00 Min.
99 Max.
Line 46 Stop bits
0 1 Stop bit
1 2 Stop bits