9 Technical data
9.1 General data
• Performance: 0.3 W (speed >5000 rpm)
• Calibration tolerance: ±5 %
• Linearity tolerance: ≤0.15 %
• Reversal tolerance: ≤0.1 %
• Superimposed ripple: ≤0.5 % peak-peak
(for τ
RC
= 0.3 ms) ≤0.25 % rms
• Temperature coefcient: ±0.05 %/K (idle)
• Armature-circuit time-constant (τ
A
): <9 µs
• Torque: 0.35 Ncm
• Rotor moment of inertia: 0.95 kgcm
2
• Permissible armature displacement: ±0.5 mm axial ±0.1 mm radial
• Vibration resistance: 100 m/s
2
≈ 10 g IEC 60068-2-6: 1996-05
(10 Hz ... 2 kHz)
• Shock resistance: 1,000 m/s
2
≈ 100 g IEC 60068-2-27: 1995-03
(6 ms)
• Operating temperature: -30°C ... +130°C
• Isolation class: B
• Protection: IP 00
IEC 60529
IP 44 with cover
• Climatic test: IEC 60068-2-3, Ca (humid heat, constant)
• Weight approx.: 0.6 kg
• EMC according to: EN 61000-6-2: 2006-03 (interference immunity)
EN 61000-6-4: 2007-09 (emitted interference)